OK, I feel stupid. I'm using a Bridgeport Series 1 Interact, and have been able to download and execute a few basic programs from Visualmill.
I've been unable to figure out how to exit/abort a running program, other than using the emergency stop (I understand the function of the motion stop button, as well as using "execute block" will pause (not stop) the program. The manual says the "stop" button on the TNC will abort the program, but it does not (key is inactive).
It also seems strange/unwieldy on this machine that there is no individual spindle stop/start ability from a button etc (has to be entered on the TNC or programmed).
Thanks for the help!
I've been unable to figure out how to exit/abort a running program, other than using the emergency stop (I understand the function of the motion stop button, as well as using "execute block" will pause (not stop) the program. The manual says the "stop" button on the TNC will abort the program, but it does not (key is inactive).
It also seems strange/unwieldy on this machine that there is no individual spindle stop/start ability from a button etc (has to be entered on the TNC or programmed).
Thanks for the help!