Good morning all
Having problems with hurco hawk rebooting
When drip feeding a long program it will always reboot its self between 45 and 55 mins every time.
Thought it might be something over heating.But if you interupt the program about 40 mins in and
the carry on it will run for another 40-50 mins but then reboots.Have used it with a 20 min converational program
and can run that program constantly all day without a problem.But if i write a 1 hour conversation program it
will reboot again after 40-50 mins again.Some times error come up motion ctr queue in axis xyz,But not all the time.
Have changed x.y and z servo boards with my other Hawk so think i can rule those out.
Any ideas and thanks to all who replied to my last post
my other hawk is up and running great
Regards Neal
Having problems with hurco hawk rebooting
When drip feeding a long program it will always reboot its self between 45 and 55 mins every time.
Thought it might be something over heating.But if you interupt the program about 40 mins in and
the carry on it will run for another 40-50 mins but then reboots.Have used it with a 20 min converational program
and can run that program constantly all day without a problem.But if i write a 1 hour conversation program it
will reboot again after 40-50 mins again.Some times error come up motion ctr queue in axis xyz,But not all the time.
Have changed x.y and z servo boards with my other Hawk so think i can rule those out.
Any ideas and thanks to all who replied to my last post
my other hawk is up and running great
Regards Neal